Rorke Data: Galaxy HDX2: SCSI to SATA 24 bay (HDX)




Recent News Releases
July 2008
Rorke Data Unveils Newest Addition to Its Value-Based, Performance-Driven Galaxy Storage Line
May 2008
Broadway Video Selects Rorke
May 2008
Rorke Data & Quantum Team for High Performance SAN Solution for Broadcast & Post Production
April 2008
Rorke Data & Primera Team at NAB
March 2008
Bell Microproducts Announces Promotion of Joe Swanson to President, Rorke Data, Inc.

 

 

 

 


SCSI to SATA 24 bay Galaxy HDX


SCSI 320 RAID SATAll Drive based

  • RAID 6 Dual Parity Support…allows a rebuild to continue even when a bad block is found during rebuild
  • Varied Drive Configurations…24 Drive bays  support 500GB,  750GB and 1TB SATAll drives
  • Huge Drive Capacities…up to 24TB of raw capacity per RAID enclosure
  • Increase in Performance…dual controller Galaxy HDX has over 550MB/S benchmark results supports the highest bandwidth applications
  • Enhanced Media Scan and Error Handling…keeps the RAID working when there are degraded or damaged hard drives
  • Embedded SNMP, Email Event Notification…firmware based event monitor sends error info to RAID administrator
  • Embedded Management and Utilities…flexible configuration of RAID LUNs, remote monitoring of RAID conditions

 

Specifications


RAID Controller Single Controller Model Only

  • Multiple arrays configurable with dedicated or global hot spare drives
  • RAID levels: RAID0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60,  and NRAID
  • Online expansion by:
  • Adding new drives
  • Copying and replacing drives with drives of larger capacity
  • Automatic background rebuild
  • Configurable stripe size and write policy per array
  • Intelligent drive handling:
  • In degraded mode: skips irreparable blocks to continue rebuild
  • In normal operation: data-block verification and repair
System Components
  • Single RAID controller configuration provides full-featured RAID functionality
  • One (1) 4U enclosure
  • One (1) RAID controller module
  • One (1) 512MB DDR RAM DIMM module preinstalled on the controller module; system supports 512MB to 2GB capacity DIMM modules
  • Three (3, N+1) hot-swappable, redundant, 405W power supply units
  • Twenty-four (24) hot-swappable drive trays
  • Two (2) hot-swappable, redundant cooling modules
  • Two (2) forearm front handles
  • One (1) optional battery backup unit (BBU)
Host Interface
  • Two (2) SCSI-320 host channels interfaced through two (2) dual-stacked VHDCIs
  • Tagged command queuing up to 256
  • Host-side ordered tag support
Drive Interface
  • Twenty-four (24) hot-swappable 3Gbps SATA II drive trays that accommodate 1-inch pitch SATA II or SATA I disk drives
  • Native Command Queuing (NCQ) support
  • Dedicated bandwidth to each connected drive
  • Automatic bad sector reassignment
Management
  • Firmware-embedded utility via LCD keypad or RS-232C terminal
  • 10/100BaseT Ethernet for out-of-band management
  • Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
  • Telnet access via onboard Ethernet port
  • Java-based RAIDWatch® Manager
  • Graphical user interface
  • Local/remote management; in-band or out-of-band via TCP/IP
  • Centralized management of multiple subsystems from one management computer
  • A variety of event notification methods: email, fax, LAN broadcast, SNMP traps, MSN messenger, ICQ, and SMS short messages
  • Secure link over SSL
Indicators
  • Onboard alarm
  • Module status LED indicators
  • Two (2) per drive tray
  • Two (2) per cooling module
  • One (1) per power supply unit
  • One (1) per BBU module
  • Three (3) per LCD panel
  • Four (4) per RAID controller module
  • Two (2) per Ethernet port
  • Module failure indication and temperature/voltage readings through I2C bus

 

 
Physical/Electrical

Interfaces
  • Four (4) 68-pin VHDCIs in dual-stacked configurations
  • Two (2) COM ports for RS-232C terminal and UPS connection (38400, n, 8, 1)
  • One (1) 10/100BaseT Ethernet port
Power Supply Module
  • Three (3) redundant, hot-swappable power supplies with PFC

Nominal Power

405W

DC Output

+3.3V: min. 0.5A, max. 20A
+5V: min. 2.5A, max. 36A
+12V: min. 1A, max. 24A
+5V SB: min. 0A, max. 0.5A

Input Frequency

47 to 63Hz

AC Input

90VAC @ 8AC , 264VAC @ 4AC with PFC


Cooling Module
  • Two (2) redundant, dual-fan cooling modules

Environmental Specifications

         

Humidity

5% to 95% (non condensing ?operating and non-operating)

Temperature

Operating : 0º to 40ºC
Non-operating : - 40º to 60ºC

Altitude

Operating : sea level to 12,000 ft
Non-operating : sea level to 40,000 ft

         
Dimensions
                   
  • Chassis without handles: 445W x 174.4H x 498D mm (17.6 x 6.86 x 19.6 inches)
  • Chassis with handles 482W x 174.4H x 514D mm (18.97 x 6.86 x 20.2 inches)
  • Package: 590W x 480H x 700D mm
System Weight       
  • Net weight: 36.5kg
  • Gross weight: 39.6kg

 

 
Download Galaxy HDX2 Brochure PDF (270k)


Contact Rorke Sales for a quote on this product
Email this page to a Friend
 
   

  © Rorke Data, Inc.    Privacy     Site Map

Phone: 800-328-8147  
952-829-0300  

  (Mon-Thur 8:30-5:30 CST)
  (Friday 8:30-5:00 CST)

Rorke Data is ISO 9001:2000 certified   