Rorke Data: Galaxy HDX2: SCSI to SATA 16 bay (HDX2)




Recent News Releases
July 2008
Rorke Data Unveils Newest Addition to Its Value-Based, Performance-Driven Galaxy Storage Line
May 2008
Broadway Video Selects Rorke
May 2008
Rorke Data & Quantum Team for High Performance SAN Solution for Broadcast & Post Production
April 2008
Rorke Data & Primera Team at NAB
March 2008
Bell Microproducts Announces Promotion of Joe Swanson to President, Rorke Data, Inc.

 

 

 

 


SCSI to SATA 16 bay Galaxy HDX2


16 bay HDX2 SCSI RAID SATAll Drive based

  • Two (2) SCSI-320 host channels; transfer rate up to 320MBps per channel.
  • Accommodates sixteen (16), 3Gbps, SATA-II (3Gbps) disk drives.
  • ASIC400 architecture with hardware RAID6.
  • Market leading I/O performance
    • Sustained RAID5 Read/Write at 566/484 MB/sec.
    • Sustained RAID6 Read/Write at 566/426 MB/sec.
  • Up to 2GB DDR memory, ECC protected.
  • Hot-swappable, life expectancy-aware battery backup.
  • Online expansion, array roaming, and centralized management.

 

Specifications


RAID Controller Single Controller Only

  • Multiple arrays each with an independent RAID level
  • Dedicated, enclosure-specific, or global hot spares.
  • RAID levels: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
  • Online RAID level migration
  • Online expansion by:
    • Adding new drives
    • Copying and replacing drives with drives of larger capacity
  • Automatic background rebuilds.
  • Independent array stripe size and write policy
  • Intelligent drive handling:
    • Degraded mode: skips irreparable blocks to continue rebuild
    • Normal: data-block verification and repair
System Components
  • Backplane-based, cableless design
  • Single-controller configuration provides full-range RAID functionalities
  • Two (2) hot-swappable, redundant, 530W power supply units (PSUs)
  • Two (2) redundant, dual thermal fans, cooling modules.
  • One (1) optional BBU
    • Sixteen (16) hot-swappable drive trays
    • LCD keypad panel
Host Interface
  • Two (2) SCSI-320 host channels; multiple SCSI IDs and LUNs
  • Interfaced through four (4) VHDCI's (for host and cascading)
  • Concurrent I/O commands
  • Tagged command queuing up to 256
Drive Interface
  • Sixteen (16) hot-swappable 3Gbps SATA-II (3Gbps) drive trays
  • NCQ and S.M.A.R.T. support
  • Dedicated bandwidth to each connected drive
Management
  • Firmware-embedded utility via LCD keypad or RS-232 serial port
  • VT-100 terminal emulation via RS-232C
  • Telnet access via Ethernet port
  • 10/100 BaseT Ethernet for out-of-band management
  • Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
  • Firmware-embedded Java-based or HTML RAIDWatch manager:
    • Graphical user interface
    • Local/remote management; in-band or out-of-band via TCP/IP
    • Centralized management to monitor and administer multiple RAID units on one screen
    • Secure link over SSL
  • Configuration Client as an independent software for event notification
  • SNMP 2.0 MIBs with get and set commands
Indicators
  • Onboard alarm
  • Module status LED indicators:
  • Module monitoring through I2C bus
  • Event notifications via Email, fax, LAN broadcast, SNMP traps, MSN messenger, and SMS short messages
  • Real-time monitoring via RAIDWatch manager

      

 
Physical/Electrical

Interfaces
  • Four (4) VHDCI SCSI ports (for host and cascading)
  • Two (2) COM ports for RS-232C terminal and UPS support
  • One (1) 10/100BaseT Ethernet port
Power Supply Module
  • Two (2) redundant, hot-swappable power supplies with PFC

Input

100VAC at 9A, 240 VAC at 4.5A with PFC (auto-switching)

47 to 63Hz

Output

(Maximum output: 530 Watts)

+12.0V

32A max.

+ 5.0V

32A max.

+ 3.3V

30A max.


Cooling Module
  • Two (2) redundant, dual-fan cooling modules

Maximum Air Flow

High speed: 90 DFM
Low speed: 70.7 CFM

Environmental Specifications

Temperature:

Operating: 0° to 40°C (32° F to 104° F) (without BBU)
Operating: 0° to 35°C (32° F to 95 ° F) (with BBU)
Non-operating: - 40° to 60°C (-40° F to 140° F)

Relative humidity:

Operating: 10% to 80% (non condensing)
Non-operating: 10 to 95% (non condensing)

Altitude:

Operating: sea level to 12,000 ft
Non-operating: sea level to 40,000 ft

         
Dimensions
                   
  • Chassis without handles: 445(W) x 130(H) x 486.7(D) mm (17.5 x 5.1 x 19.2 inches)
  • Chassis with handles: 482.6(W) x 131(H) x 534.6(D) mm (19 x 5.2 x 21 inches)
  • Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
System weight   (without drives)    
  • Net weight: 28.5kg (62.7 pounds)
  • Gross weight: 30.5kg (67.1)

 

 
Download Galaxy HDX2 Brochure PDF (270k)


Contact Rorke Sales for a quote on this product
Email this page to a Friend
 
   

  © Rorke Data, Inc.    Privacy     Site Map

Phone: 800-328-8147  
952-829-0300  

  (Mon-Thur 8:30-5:30 CST)
  (Friday 8:30-5:00 CST)

Rorke Data is ISO 9001:2000 certified   