SAS to SAS/SATA
16 bay Galaxy HDX2 |
16 bay HDX2 SAS RAID SAS/SATAll Drive based with SAS Expansion
- SAS to SAS/SATA-II RAID subsystem
- Redundant or single RAID controller
- Galaxy multi-pathing, load-balancing software
- 4 or 2 SAS 4x wide host ports
- Hardware RAID6 engine by dedicated ASIC400 chipsets
- Superior performance w/ uncomplicated connectivity
- 16 SAS or SATA-II (3Gbps) disk drives
- Expansion to 80TB via a 4x wide expansion port
- Corresponding JBODs: S16S-J1000-R (dual-controller); S16S-J1000-S (single-controller)

|
| Specifications |
RAID Controller Single / Dual Controller Models Available
- Hardware RAID5 & RAID6
- Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID, and JBOD
- RAID Migration
- Configurable stripe size and write policy per array
- Multiple Global, Dedicated, & Enclosure-specific hot-spares
- Intelligent Drive Handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
Host Interface
- 2 SAS wide ports per controller
- 12Gbps bandwidth (half duplex) per port
- Concurrent I/O commands
- Tagged command queuing up to 1024
- Max. command queue up to 1024
- Fault-tolerant host links with multi-pathing software
- Included cables:
- 2 x SFF-8088-to-SFF-8470 120cm cables
Drive Interface
- 16 3.0Gbps SAS/SATA-II, hot-swappable drive trays
- Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
- S.M.A.R.T. and NCQ support
- Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
- In-band enclosure service through the expansion links from expansion enclosures
- Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
- MUX kits with port selectors for dual-controller access to SATA drives
System Components
- High density, smartly managed 3U enclosure
- One (1) SAS expansion port per controller accepts up to 4 SAS JBOD chassis [ only 3 chassis with dual controller]
- Dual redundant or single RAID controller
- One DIMM module with capacities from 512MB to 2GB
- Redundant, hot-swappable 530W power supply units
- Redundant, dual-speed cooling modules
- Sixteen (16), hot-swappable drive trays
- Two (2) forearm handles
- Li-Ion battery backup unit (BBU), life expectancy and charge level aware
Management
- COM1 serial port for local access to firmware-embedded utility
- COM2 for UPS connection
- Automated cache flush and caching mode operation per enclosure status
- GUI, Telnet, and SSH system monitoring via Ethernet
- Browser-based or Java-based RAIDWatch manager software
- Firmware-embedded manager via RS-232C (audio jack) that is platform independent
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
- LCD keypad panel for monitoring and access to all configuration options
- Variable logical drive options per DIMM size
- Module status LED indicators:
- Two (2) per drive tray
- Seven (7) per controller module
- One (1) per power supply unit
- One (1) per BBU module
- Two (2) per cooling module
- Presence detection & thermal sensors via I2C bus
|
|
| Physical/Electrical |
Power Supply Module
- Redundant hot-swappable power supplies with PFC
Input |
100VAC at 9A, 240VAC at 4.5A with PFC (auto-switching) |
47 to 63Hz |
Output |
(Maximum output: 530 Watts) |
+12.0V |
32A max. |
+ 5.0V |
32A max. |
+3.3V |
30A max. |
Cooling Module
- Redundant dual-thermal-fan cooling modules
Maximum air flow: |
90CFM (high speed); 70.7CFM (low speed) |
Environmental Specifications
Operating temperature |
5º to 40ºC (35°C if battery is applied) |
Non-operating temperature |
- 40º to 60ºC |
Relative humidity |
5 to 95%, non-condensing |
Operating altitude |
Operating: 0 to 12,000 ft |
Dimensions
- Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
System weight
- Net weight: 28.5kg (62.7 pounds)
- Gross weight: 30.5kg (67.1 pounds)
|
|
| |
|
|