Fibre to SATA 16 bay Galaxy HDX2

 


Our most popular Award winning product.

  • RAID 6 Dual Parity Support…allows a rebuild to continue even when a bad block is found on a different disk drive
  • Varied Drive Configurations…16 Drive bays  support 500GB, 750GB and 1TB SATAll drives
  • Varied Host connectivity…4Gb Fibre, SAS,  and ISCSI Host connectivity shows the versatility needed for all
  • Huge Drive Capacities…up to 16TB of raw capacity per RAID enclosure with the new 1000GB SATAll disk drives
  • Increase in Performance…dual controller Galaxy HDX2 has over 720MB/S Fibre Channel benchmark results supports the highest bandwidth applications
  • Increased  Fibre Host Connections…failover multiipath and clustering options allow numerous Fibre Hosts to connect to the Galaxy
  • Enhanced Media Scan and Error Handling…keeps the RAID working when there are degraded or damaged hard drives
  • Embedded SNMP, Email Event Notification…firmware based event monitor sends error info to RAID administrator
  • Embedded Management and Utilities…flexible configuration of RAID LUNs, remote monitoring of RAID conditions

 

Specifications


RAID Controller  Single / Dual Controller Models Available

  • Hardware RAID parity computing
  • Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
  • RAID Migration
  • Configurable stripe size and write policy per array
  • Multiple Global, Dedicated, & Enclosure-specific hot-spares
  • Intelligent Drive Handling:
  • In degraded mode: skips irreparable blocks to continue rebuild
  • In normal operation: data-block verification and repair

Host Interface

  • Four (4) FC-4G host port w/HUB functions per controller
  • Concurrent I/O commands
  • Tagged command queuing up to 256
  • Adaptive cache write policies
Drive Interface
  • Sixteen (16) 3.0Gbps SATA-II (3Gbps) , hot-swappable drive trays
  • Accommodates 1-inch pitch, 3.5-inch SATA-II (3Gbps) disk drives
  • S.M.A.R.T. and NCQ support· Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive
      

System Components

  • Heavy duty 3U enclosure
  • Single or Dual-redundant RAID controller modules
  • One (1) 512MB DDR RAM DIMM module (default, supports up to 2GB in size) on each controller
  • Two (2), hot-swappable, redundant, 530W power supply units
  • Two (2), redundant, dual-speed cooling modules
  • Sixteen (16), hot-swappable drive trays
  • Two (2) forearm handles
  • LCD keypad panel
  • Li-Ion, life expectancy & charge level aware battery backup unit (BBU)
Management
  • COM1 serial port for local access to firmware-embedded utility
  • COM2 for UPS connection
  • GUI, Telnet, and SSH system monitoring via Ethernet
  • Browser-based or Java-based RAIDWatch manager software
  • Firmware-embedded manager via RS-232C (audio jack) that is platform independent
  • Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
  • LCD keypad panel to all configuration options
  • Variable logical drive options per DIMM size
  • Module status LED indicators:
    • Two (2) per drive tray
    • Seven (7) per controller module
    • One (1) per power supply unit
    • One (1) per BBU module
    • Two (2) per cooling module
  • Module failure alert through I 2 C bus
             

 

 
Physical/Electrical

Interfaces
  • One (1) Fast Ethernet management port
  • Two (2) serial COM port (38400, n, 8, 1)
  • Power Supply Module Two (2) redundant hot-swappable power supplies with PFC

Input

100~240VAC with 530W PFC (auto-switching)

47 to 63Hz

Output

(Maximum output: 530 Watts)

+12.0V

30A max.

+ 5.0V

32A max.

+ 3.3V

32A max.


Cooling Module
  • Two (2) redundant, dual-fan cooling modules Maximum Air Flow: High speed: 48.12 CFM  

Maximum air flow:

High speed: 90 CFM
Low speed: 70 CFM

Environmental Specifications  

Operating temperature:

0º to 40ºC (35ºC w/ battery)

Non-operating temperature:

- 40º to 60ºC

Relative humidity:

5 to 95%, non-condensing

Altitude:

Operating: sea level to 12,000 ft
Non-operating: sea level to 40,000 ft

         
Dimensions
                   
  • Chassis without handles: 445(W) x 130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
  • Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm (19 x 5.2 x 19.9 inches)
  • Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
System weight
  • Net weight: 28kg
  • Gross weight: 31kg (without drives)

 

 