Fibre to SATA 12 / 8 bay Galaxy HDX


12 / 8 bay HDX Fibre Channel RAID SATAll Drive based

  • Two 4G FC host channels
  • 2U chassis proving up to 6TB of storge capacity
  • DDR Memery up to 2GB
  • Dual-speed cooling fans to reduce system noise

 

Specifications


RAID

  • Multiple arrays configurable with dedicated or global hot spares
  • RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
  • Online expansion by:
    • Adding new drives
    • Copying and replacing drives with drives of larger capacity
  • Automatic background rebuildsConfigurable stripe size and write policy per arrayIntelligent drive handling:
    • In degraded mode: skips irreparable blocks to continue rebuild
    • In normal operation: data-block verification and repair
Host Interface
  • Two (2) FC-4G through two (2) SFP host ports
  • Concurrent I/O commands
  • Tagged command queuing up to 256
  • Variable stripe size per logical drive
  • Optimization setting for random or sequential I/Os
Drive Interface
  • Twelve (12) or eight (8) 3Gbps SATA-II (3Gbps) , hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I or SATA-II (3Gbps) disk drives
  • Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive
System Components
  • Single controller configuration provides full RAID functionalities
    • One (1) enhanced 2U enclosure
    • One (1) RAID controller module
    • One (1) 256MB DDR RAM DIMM module (pre-installed on the controller module)
    • Two (2), hot-swappable, redundant, 350W power supply units
    • Three (12 bay) or Two (8bay), hot-swappable, redundant, single-fan cooling modules running in high/low speeds
    • Twelve (12) or eight (8), hot-swappable drive trays
    • Two (2) front handles
    • Optional battery backup unit
Management

Front LCD control panel for setup and configuration10/100 BaseT Ethernet for out-of-band management One (1) RS-232C serial port for local access to firmware-embedded utility Firmware-embedded Java-based RAIDWatch® GUI manager:

  • VT-100 terminal emulation via RS-232C
  • Telnet access via onboard Ethernet port
  • Cross-platform, remote administration with SSL
  • Out-of-band access via Ethernet
  • Centralized management to monitor and administer multiple RAID units on one screen
  • Configuration client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps, MSN messenger,SMS short messages, and the configuration utility screen
Indicators

Onboard alarm is triggered when one of the following modules fails:

  • RAID controller module
  • Cooling module
  • Power supply unit
  • Hard drive
  • BBU module

Module status LED indicators:

  • Two (2) per drive tray
  • One (1) per cooling module
  • One (1) per power supply unit
  • One (1) per BBU module
  • Three (3) per LCD panel
  • Five (5) per RAID controller module
  • Two (2) per Ethernet port

Module failure alert through I2C bus

Intelligent Drive Handling

If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives, power-failure management, and bad-drive handling during LD expansion.

Task Scheduler

The Task Scheduler is combined with Media Scan so that the scanning operation can be scheduled beginning at a specified start time and repeating at the configurable intervals. The operation is thus hands free. Each such schedule can be defined to operate on individual hard drives, all drives of a certain class, all member drives of a specified logical drive, or all member drives of all logical drives.

 

 
Physical/Electrical

Interfaces
  • Two (2) SFP ports for host connections
  • One (1) COM port (38400, n, 8, 1)
  • One (1) 10/100BaseT Ethernet port
Power Supply Module
  • Two (2) redundant hot-swappable power supplies with PFC

Input

100VAC at 6A, 240VAC at 3A with PFC (auto-switching)

47 ~ 63Hz

Output

(Maximum output: 350 Watts)

+12.0V

25A max.

+ 5.0V

25A max.

+ 3.3V

20A max.


Cooling Module
  • Three (A12F) or two (A08F) redundant single-fan cooling modules

Maximum air flow
(each module)

High speed: 31.8 CFM
Low speed: 20.1 CFM

Environmental Specifications

Operating temperature

0° to 40°C

Non-operating temperature

- 40º to 60ºC

Relative humidity

5 ~ 95%, non-condensing

Operating altitude

Operating: 0 ~ 12,000 ft
Non-operating: 0 to 40,000 ft

         
Dimensions
                   
  • Chassis without handles: 446(W) x 88(H) x 490(D) mm
  • Chassis with handles: 482 (W) x 88(H) x 505(D) mm
  • Package: 381H x567W x 772D mm
System weight       
  • Net weight: 23.5kg
  • Gross weight: 25kg

 


Contact Rorke Sales for a quote on this product
Email this page to a Friend
 
   